Home
About CMI
Installation
Braces
Order Spacers
Photos
Contact Us
e-mail me


CMI's Carrier Pipe Braces

 

  Model B-CS

  Model B-CS

Carbon Steel Carrier Pipe Braces - Model B-CS

 

Material Specifications

 
 

Band and Risers

Band - 14 Gauge

Riser - *12 Gauge

Carbon Steel

    *10 Gauge if required

Runner - UHMW Polymer Plastic Runner

Tensile psi (min) 75,000

Yield psi (min) 30,000

Brinell (max) Hardness 202

 

Liner - Polyvinyl Chloride

Thickness - .090" (2.29 mm) Minimum

Water Absorption - Maximum 1%

Dielectric Strength - 1/8" (3.18 mm) thick

                              60,000 VPM

Hardness - Durometer "A" 85-90

Tivar - 1000

Polyvinyl Chloride

Thickness - .090" (2.29 mm) Minimum

Water Absorption - Maximum 1%

Dielectric Strength - 1/8" (3.18 mm) thick

   

Welding

All risers are welded to the band by MIG Welding

Coating

Coal tar with epoxy coating - 16 mils

Sizes

Available from 4" and larger carrier pipe

   

**Number of risers depend on size of pipe and number of spacers per joint

   Bands will be 8" or 12" as required

   

   

  Model B-SS

  Model B-SS

Stainless Steel Carrier Pipe Braces - Model B-SS

   

Material Specifications

 
   

Band and Risers

Band - 14 Gauge

Riser - *12 Gauge

T-304 Stainless Steel

    *10 Gauge T-304 Stainless Steel if required

Runner - UHMW Polymer Plastic Runner

Tensile psi (min) 75,000

Yield psi (min) 30,000

Brinell (max) Hardness 202

   

Liner - Polyvinyl Chloride

Thickness - .090" (2.29 mm) Minimum

Water Absorption - Maximum 1%

Dielectric Strength - 1/8" (3.18 mm) thick

                              60,000 VPM

Hardness - Durometer "A" 85-90

Tivar - 1000

Tensile Yield - D638 ASTM 3100 psi

Ultimate Tensile - D638 ASTM 6200 psi

Elongation at Break - D638 ASTM 300%

   

Welding

All risers are welded to the band by MIG Welding

All welds are passivated to protect the integrity of the pipe

Assembly Hardware

T-304 Stainless Steel

3/8" - 18/2 1/2"

3/8" Hex Nuts

Sizes

Available from 4" and larger carrier pipe

   

**Number of risers depend on size of pipe and number of spacers per joint

   Bands will be 8" or 12" as required

   

|Home| |About CMI| |Installation| |Braces| |Order Spacers| |Photos| |Contact Us|

Copyright 2008 Contractors Manufacturing, Inc.